Features
Efficient
• 5-parameter lipid panel & individual tests
• Results in ≤ 2 minutes
• Sample types: whole blood, serum, plasma
Ease of Use
• Portable, compact, ergonomic design
• Patient friendly
• 3 simple steps: insert strip, apply sample with a capillary transfer tube, read results
Premium Features
• Cardiac Risk Assessment
• Test devices with 18-month shelf life
• Room temperature storage
• Clinically proven accuracy
• 5-parameter lipid panel & individual tests
• Results in ≤ 2 minutes
• Sample types: whole blood, serum, plasma
Ease of Use
• Portable, compact, ergonomic design
• Patient friendly
• 3 simple steps: insert strip, apply sample with a capillary transfer tube, read results
Premium Features
• Cardiac Risk Assessment
• Test devices with 18-month shelf life
• Room temperature storage
• Clinically proven accuracy
Specification
• Feature Specification
• Analyzer Type Handheld Meter
• Methodology Reflectance Photometry
• Test Parameters • Total Cholesterol (CHOL)
• High-Density Lipoprotein (HDL)
• Triglycerides (TRIG)
• Calculated Low-Density Lipoprotein (LDL)
• CHOL/HDL ratio
• Risk Assessment (CHD) Four scoring methods:
1. PROCAM
2. Framingham
3. ACC/AHA (10-year)
4. ACC/AHA (lifetime)
• Time to Results ≤ 2 minutes
• Memory 200 Results with Date/Time
• HCT Range 30-50%
• Specimen Volume 10μL (Individual Tests) or 35μL (3-in-1 Lipid Panel Test)
• Specimen Type Capillary or Venous Whole Blood, Serum or Plasma
• CHOL Measurement Range 100-500 mg/dL (2.59-12.93 mmol/L)
• HDL Measurement Range 15-100 mg/dL (0.39-2.59 mmol/L)
• TRIG Measurement Range 45-650 mg/dL (0.51-7.34 mmol/L)
• PC Interface Mini-USB
• Operating Conditions 15-40°C (59-104°F) < 90% RH
• Storage Conditions Meter: 0-50°C (32-122°F) < 90% RH
Strip: 2-30°C (36-86°F)
• Strip Shelf Life 18 months
• Power Source 4 AAA Batteries or AC Adapter
• Battery Life >1,000 Tests
• Meter Dimensions 137 x 79 x 26 mm (5.4” x 3.1” x 1.0”)
• Display Dimensions 50 x 50 mm (2.0” x 2.0”)
• Weight Excluding Batteries
• Analyzer Type Handheld Meter
• Methodology Reflectance Photometry
• Test Parameters • Total Cholesterol (CHOL)
• High-Density Lipoprotein (HDL)
• Triglycerides (TRIG)
• Calculated Low-Density Lipoprotein (LDL)
• CHOL/HDL ratio
• Risk Assessment (CHD) Four scoring methods:
1. PROCAM
2. Framingham
3. ACC/AHA (10-year)
4. ACC/AHA (lifetime)
• Time to Results ≤ 2 minutes
• Memory 200 Results with Date/Time
• HCT Range 30-50%
• Specimen Volume 10μL (Individual Tests) or 35μL (3-in-1 Lipid Panel Test)
• Specimen Type Capillary or Venous Whole Blood, Serum or Plasma
• CHOL Measurement Range 100-500 mg/dL (2.59-12.93 mmol/L)
• HDL Measurement Range 15-100 mg/dL (0.39-2.59 mmol/L)
• TRIG Measurement Range 45-650 mg/dL (0.51-7.34 mmol/L)
• PC Interface Mini-USB
• Operating Conditions 15-40°C (59-104°F) < 90% RH
• Storage Conditions Meter: 0-50°C (32-122°F) < 90% RH
Strip: 2-30°C (36-86°F)
• Strip Shelf Life 18 months
• Power Source 4 AAA Batteries or AC Adapter
• Battery Life >1,000 Tests
• Meter Dimensions 137 x 79 x 26 mm (5.4” x 3.1” x 1.0”)
• Display Dimensions 50 x 50 mm (2.0” x 2.0”)
• Weight Excluding Batteries
Reviews
There are no reviews yet.